AX Workflow Manager 6.5 - 64-Bit Installer - Skelta Site Problem

issue
Default Skelta websites are not created on Windows 2008 64-bit server after running the Workflow Manager Configuration Wizard

Cause

Interference with the existing Windows 2008 default website bindingsBefore running the Workflow Manager Configuration Wizard on a Window

solution
s 2008 64-bit server,open the IIS Manager and right-click on the Default Web Site,click on the Edit Bindings and delete all of the Site Binding with the one exception of the HTTP binding. Run the Workflow Manager Configuration Wizard and use the default setting set for the Workflow services. The two default Skelta websites, Central Config and the Enterprise Console will install properly on the Windows 2008 64-bit server. See attachment for complete instructions on installing AX Workflow Manager on Server 2008 R2 64-bit.